500 Series
A Block
AA Block
ACT-2V
ACT-SI
ACT-SV
APT-35L
AL Block
B Block
B S/H Block
BD100
BD120
BD300
BD320
BM100
BM120
BM303
BM320
BM916
C-Block
C1-Block
C600
CSM-1
D-Block
DCC-8
DIN100
DIN120
DIN130
DIN140
DIN200
DIN300
DIN320
DIN350
DIN360
DIN370
DIN380
DIN400
DIN500
DIN700
DIN710
DIN720
DIN901
DIN902
E Block
EI400
E1-1C0 / E1-1C3
E1-FREQ
E1-VAR Series
E1-W Series
FTI-1
FTI-1D
G Block
H Block
I Block
J Block
K Block
KK Block
L Block
L900
L900RG Mark II
M Block
MDM-11
MicroDIN
MicroFREQ A-F
MicroFREQ F-A
MicroFREQ F-F
MicroMATH
MIN130
MIN140
MIN200
MIN300
MIN310
MIN320
MIN350
MIN360
MIN380
MIN400
MIN500
MIN710
MIN720
N Block
P Block
PU700
QC Series
R Block
RTR-2
RTI-2
RTI-2D
RTM-8
RTP-2
RTT-2
RTT-3
S Block
SC200
SEL300
SI300-20
SI300 & SI310
SI320, SI330 & SI340
T Block
T100
T120
T130
TCI-2
TCI-2D
TCR-2
TCT-3
VVH-3
WVT-3
WWH-3

TEMPERATURE CONVERTERS:

If the product you require is not available to buy online, please complete the Enquiry Form.

RTR-2 - PT100 2 Wire Head Mounting Transmitter


RTR-2Function: Non-isolating multi-range 2 wire temperature transmitter which will convert a PT100 input into a standardised load-independent 4 to 20mA current output, linearly proportional to the measured temperature. The RTR-2 instrument is housed in a metal enclosure suitable for mounting in DIN B connection heads and which gives excellent RFI immunity. The RTR-2 has excellent lead resistance compensation and PT100 linearisation conforming to BS1904 characteristics. Calibration is performed by means of a DIP switch array for coarse settings and two potentiometers for fine tuning. The calibration devices are located behind the metal top cover.

Power supply: loop powered




TCR-2 - Thermocouple 2 Wire Head Mounting Transmitter


TCR-2Function: Non-isolating multi-range 2 wire temperature transmitter which will convert a thermocouple input into a standardised load-independent 4 to 20mA current output, linearly proportional to the measured temperature. There are three basic models which cover the various thermocouple types. TCR-2a covers types K, J and T; TCR-2b covers type E and TCR-2c covers types R and S. The TCR-2 instrument is housed in a metal enclosure suitable for mounting in DIN B connection heads and which gives excellent RFI immunity. Calibration is performed by means of a DIP switch array for coarse settings and two potentiometers for fine tuning. The calibration devices are located behind the metal top cover.

Power supply: loop powered




RTP-2 - Temperature Transmitter with built-in PT100


RTP-2Function: An integral PT100 and 2 wire transmitter that will output a standardised load-independent 4 to 20mA current, linearly proportional to the measured temperature. The RTP-2 is housed in an IP65 polycarbonate plastic enclosure suitable for use in high humidity applications. Calibration is performed by changing two resistors for coarse settings and tweaking two potentiometers, Span and Zero, for fine tuning. Both the resistors and the potentiometers are located inside the housing.

Application Notes: The RTP-2 is ideally suited for use in greenhouses, agricultural applications and climate control systems.

Power supply: loop powered




RTT-2 - RTD 2 Wire DIN Rail Mounting Transmitter


RTT-2Function: Non-isolating multi-range 2 wire temperature transmitter which will convert an RTD input into a standardised load-independent 4 to 20mA current output, linearly proportional to the measured temperature. The RTT-2 instrument is housed in a low profile polycarbonate plastic enclosure suitable for mounting on TS35 DIN rail. The RTT-2 has excellent lead resistance compensation and PT100 linearisation conforming to BS1904 characteristics. Calibration is performed by means of an internal DIP switch array for coarse settings and two potentiometers brought out to the front panel for fine tuning. The RTT-2 is equipped with "test" terminals which enable monitoring of the output current by measuring the voltage across an internal 10 ohm resistor without breaking the current loop.

Options include: PT50, PT500, CU10 and NI120 RTD inputs.

Power supply: loop powered




RTI-2 - RTD 2 Wire Isolating Transmitter


RTI-2Function: Isolating multi-range 2 wire temperature transmitter which will convert any 2 or 3 wire RTD input into a 4 to 20mA current. The RTI-2 is housed in a polycarbonate plastic enclosure suitable for mounting on DIN rail. The RTI-2 has exceptional input to output high common mode rejection ratio and a high degree of filtering to eliminate false output signals, providing a low ripple output current. PT100 linearisation conforms to BS1904 characteristics. Calibration is performed by means of an internal DIP switch array for coarse settings and two potentiometers brought out to the front panel for fine tuning. The RTI-2 is equipped with "test" terminals which enable monitoring of the output current by measuring the voltage across an internal 10 ohm resistor without breaking the current loop.

Options Include: 2 x RTD inputs to give an output proportional to the temperature differential.

Power supply: loop powered




TCI-2 - Thermocouple 2 Wire Isolating Transmitter


TCI-2Function: Isolating multi-range 2 wire temperature transmitter which will convert a thermocouple input into a linearised, load independent 4 to 20mA current. The TCI-2 is housed in a polycarbonate plastic enclosure suitable for mounting on DIN rail. The TCI-2 has exceptional input to output high common mode rejection ratio and a high degree of filtering to eliminate false output signals, providing a low ripple output current. Linearisation is carried out by eight segment piece-wise linearisation circuitry. Calibration is performed by means of an internal DIP switch array for coarse settings and two potentiometers brought out to the front panel for fine tuning. The TCI-2 is equipped with "test" terminals which enable monitoring of the output current by measuring the voltage across an internal 10 ohm resistor without breaking the current loop.

Power supply: loop powered




RTI-2D - RTD 2 Wire Isolating Transmitter with Integral Display


RTI-2DFunction: Isolating multi-range 2 wire temperature transmitter which will convert any 2 or 3 wire RTD input into a 4 to 20mA current. The RTI-2D is housed in a polycarbonate plastic enclosure suitable for mounting on DIN rail. The RTI-2D has exceptional input to output high common mode rejection ratio and a high degree of filtering to eliminate false output signals, providing a low ripple output current. PT100 linearisation conforms to BS1904 characteristics. Calibration is performed by means of an internal DIP switch array for coarse settings and two potentiometers brought out to the front panel for fine tuning. The RTI-2D is equipped with "Monitor" terminals which enable monitoring of the output current by measuring the voltage across an internal 10 ohm resistor without breaking the current loop.

Options include: 2 x RTD inputs to give an output proportional to the temperature differential.

Power supply: loop powered




TCI-2D - Thermocouple 2 Wire Isolating Transmitter with Integral Display


TCI-2DFunction: Isolating multi-range 2 wire temperature transmitter which will convert a thermocouple input into a linearised, load independent 4 to 20mA current. The TCI-2D is housed in a polycarbonate plastic enclosure suitable for mounting on DIN rail. The TCI-2D has exceptional input to output high common mode rejection ratio and a high degree of filtering to eliminate false output signals, providing a low ripple output current. Linearisation is carried out by eight segment piece-wise linearisation circuitry. Calibration is performed by means of an internal DIP switch array for coarse settings and two potentiometers brought out to the front panel for fine tuning. The TCI-2D is equipped with "Monitor" terminals which enable monitoring of the output current by measuring the voltage across an internal 10 ohm resistor without breaking the current loop.

Power supply: loop powered




RTT-3 - RTD 3 Wire Isolating Transmitter


RTT-3Function: Isolating multi-range 3 wire temperature transmitter which will convert any 2 or 3 wire RTD input into a 4 to 20mA current. The RTT-3 is housed in a polycarbonate plastic enclosure suitable for mounting on DIN rail. The RTT-3 has exceptional input to output high common mode rejection ratio and a high degree of filtering to eliminate false output signals, providing a low ripple output current. PT100 linearisation conforms to BS1904 characteristics. Calibration is performed by means of three internal coarse range resistors and two potentiometers (Span and Zero) brought out to the front panel for fine tuning. The RTT-3 three wire configuration allows a loop load of 300 ohms at a supply voltage of just 10 Volts and 1000 ohms at a supply voltage of 24 Volts.

Options include: 2 x 2 wire RTD inputs to give an output proportional to the temperature differential.

Power supply: DC powered




TCT-3 - Thermocouple 3 Wire Isolating Transmitter


TCT-3Function: Isolating multi-range 3 wire temperature transmitter which will convert any thermocouple input into a 4 to 20mA current. The TCT-3 has exceptional input to output high common mode rejection ratio and a high degree of filtering to eliminate false output signals, providing a low ripple output current. Auto-zero, chopper stabilised front-end circuitry provides a superb thermal stability and allows input spans as low as 1.5mV (equivalent to 40°C for type K thermocouple). Calibration is performed by means of three internal coarse range resistors and two potentiometers (Span and Zero) brought out to the front panel for fine tuning. The TCT-3 three wire configuration allows a loop load of 300 ohms at a supply voltage of just 10 Volts and 1000 ohms at a supply voltage of 24 Volts.

Power supply: DC powered




top back